1-phase frequency converter

1-phase frequency converter

SpeedControl 1145

The compact design has a very low noise level as there are no fans in the frequency converter. As the frequency converter is therefore maintenance-free, it makes it suitable in many product configurations. At the same time, all parts are integrated in the product and therefore no external capacitors or inductors are needed. SpeedControl 1145 does not have built-in active cooling.

Technical specification – SpeedControl 1145
Supply voltage
200 – 253 VAC – 50/60Hz
Supply current
Max 16A
Output current
3 x 10A eller 3x14A
Output power
2000W or 3000W
Operating temperature
– 10 to 60°C
Storage temperature
– 20 to 60°C
IP classification and humidity in use
IP 00 – IP 20 0-90% RH, no condensation allowed
Size
Depending on heat sink
Inrush Current.
Max 16A
Size
16A
diversion current
> 3.5 mA (only frequency-converter)
HW Stop interface
Acts as a contact between terminals 1 and 2.
Protection
Motor short circuit, Motor Blocking, Motor phase loss.
Internal temp. Protection
Stops at 105 ° C (Max. 114 ° C) measured in the power module.
Power og Motor terminaler
Clamp: 1.0 – 4.0mm
HW stop and control terminals
Clamp: Max. 1.5mm
Modbus Interface.
A, B, GND and 24VDC/50mA.
Cooling
Adequate cooling is mandatory. Place the frequency converter in the air flow.

Engine selection

When the SpeedControl 1145 is to control a compressor motor, it is important that the SpeedControl 1145 is tuned correctly for exactly that motor.

We have already tuned the SpeedControl 1145 to a number of known compressor models and these have each got their own motor profile, which is either selected via ModBus interface or using a small add-on print that translates ModBus to 0-10V signal. If add-on print is selected, the motor selection is easily set via dip switches.

Tuning of new profiles

If you do not find exactly your selected compressor in the engine profile list, we are happy to help tune the SpeedControl 1145 so that it controls your compressor as best as possible.

As a rule, new profiles are tuned in our workshop, but in some cases it may be possible to perform the tuning remotely online.

Cooling plate

By default, you can choose between cooling plate with horizontal or vertical ribs or ColdPlate. If you want a different cooling plate, a solution can be found in collaboration with our development department