SpeedControl 1002 has no built-in fans, ensuring an extremely low noise level. This also means that the frequency inverter is maintenance-free. The compact design, where all components are integrated into the inverter itself, eliminating the need for external capacitors or inductors, makes it suitable for many product configurations. SpeedControl 1002 does not have built-in active cooling.
SpeedControl 1002
|
|
---|---|
Supply voltage
|
3 x 380-420 VAC – 50/60Hz
|
Supply current
|
3 x 16A at 400VAC
|
Output current
|
Max 3 x 16A
|
Output power
|
Max. 7500W
|
Operating temperature
|
– 10 to 60°C
|
Storage temperature
|
– 20 to 60°C
|
IP classification and humidity in use
|
IP 00 0-90% RH, no condensation allowed
|
Size
|
Depending on heat sink
|
Inrush Current.
|
IP 00 0-90% RH, no condensation allowed
|
Size
|
16A
|
diversion current
|
> 3.5 mA (only frequency-converter)
|
HW Stop interface
|
Acts as a contact between terminals 1 and 2.
|
Protection
|
Motor short circuit, Motor Blocking, Motor phase loss.
|
Internal temp. Protection
|
Stops at 105 ° C (Max. 114 ° C) measured in the power module.
|
Power og Motor terminaler
|
Clamp: 1.0 – 4.0mm
|
HW stop and control terminals
|
Clamp: Max. 1.5mm
|
Modbus Interface.
|
A, B, GND and 24VDC/50mA
|
Cooling
|
Adequate cooling is mandatory. Place the frequency converter in the air flow.
|
When the SpeedControl 1002 is to control a compressor motor, it is important that the SpeedControl 1002 is tuned correctly for exactly that motor.
We have already tuned the SpeedControl 1002 to a number of known compressor models and these have each got their own motor profile, which is either selected via ModBus interface or using a small add-on print that translates ModBus to 0-10V signal. If add-on print is selected, the motor selection is easily set via dip switches.
Download ‘motor profiles‘ to see which compressor models, we have already tuned for.
If you do not find exactly your chosen compressor in the engine profile list, we are happy to help tune the SpeedControl 1002 so that it controls your compressor as best as possible.
As a rule, new profiles are tuned in our workshop, but in some cases it may be possible to perform the tuning remotely online.
By default, SpeedControl 1002 is built on a Cold Plate. If you want a different cooling plate, it is possible to replace it with another model in collaboration with our development department.
Do you want to discuss if SpeedControl 1002 is the right choice for your product configuration?
Since 1969, we have been supplying electronics for control, regulation and control to quality-conscious companies