3-phase frequency converter

3-phase frequency converter

SpeedControl 1002

Technical specifications

SpeedControl 1002 – 7500
Supply voltage
3 x 380-420 VAC – 50/60Hz
Supply current
3 x 16A at 400VAC
Output current
Max 3 x 16A
Output power
Max. 7500W
Operating temperature
– 10 to 60°C
Storage temperature
– 20 to 60°C
IP classification and humidity in use
IP 00 0-90% RH, no condensation allowed
Size
Depending on heat sink
Inrush Current.
IP 00 0-90% RH, no condensation allowed
Size
16A
diversion current
> 3.5 mA (only frequency-converter)
HW Stop interface
Acts as a contact between terminals 1 and 2.
Protection
Motor short circuit, Motor Blocking, Motor phase loss.
Internal temp. Protection
Stops at 105 ° C (Max. 114 ° C) measured in the power module.
Power og Motor terminaler
Clamp: 1.0 – 4.0mm
HW stop and control terminals
Clamp: Max. 1.5mm
Modbus Interface.
A, B, GND and 24VDC/50mA
Cooling
Adequate cooling is mandatory. Place the frequency converter in the air flow.

Engine selection

When the SpeedControl 1002 is to control a compressor motor, it is important that the SpeedControl 1002 is tuned correctly for exactly that motor.

We have already tuned the SpeedControl 1002 to a number of known compressor models and these have each got their own motor profile, which is either selected via ModBus interface or using a small add-on print that translates ModBus to 0-10V signal. If add-on print is selected, the motor selection is easily set via dip switches.

Tuning of new profiles

If you do not find exactly your chosen compressor in the engine profile list, we are happy to help tune the SpeedControl 1002 so that it controls your compressor as best as possible.

As a rule, new profiles are tuned in our workshop, but in some cases it may be possible to perform the tuning remotely online.

Cooling plate

By default, SpeedControl 1002 is built on a ColdPlate. If you want a different cooling plate, it is possible to replace it with another model in collaboration with our development department.

Do you want to discuss if SpeedControl 1002 is the right choice for your product configuration?