The compact design has a very low noise level as there are no fans in the frequency converter. As the frequency converter is therefore maintenance-free, it makes it suitable in many product configurations. At the same time, all parts are integrated in the product and therefore no external capacitors or inductors are needed. SpeedControl 1145 does not have built-in active cooling.
Technical specification – SpeedControl 1145
|
|
---|---|
Supply voltage
|
200 – 253 VAC – 50/60Hz
|
Supply current
|
Max 16A
|
Output current
|
3 x 10A eller 3x14A
|
Output power
|
2000W or 3000W
|
Operating temperature
|
– 10 to 60°C
|
Storage temperature
|
– 20 to 60°C
|
IP classification and humidity in use
|
IP 00 – IP 20 0-90% RH, no condensation allowed
|
Size
|
Depending on heat sink
|
Inrush Current.
|
Max 16A
|
Size
|
16A
|
diversion current
|
> 3.5 mA (only frequency-converter)
|
HW Stop interface
|
Acts as a contact between terminals 1 and 2.
|
Protection
|
Motor short circuit, Motor Blocking, Motor phase loss.
|
Internal temp. Protection
|
Stops at 105 ° C (Max. 114 ° C) measured in the power module.
|
Power og Motor terminaler
|
Clamp: 1.0 – 4.0mm
|
HW stop and control terminals
|
Clamp: Max. 1.5mm
|
Modbus Interface.
|
A, B, GND and 24VDC/50mA.
|
Cooling
|
Adequate cooling is mandatory. Place the frequency converter in the air flow.
|
When the SpeedControl 1145 is to control a compressor motor, it is important that the SpeedControl 1145 is tuned correctly for exactly that motor.
We have already tuned the SpeedControl 1145 to a number of known compressor models and these have each got their own motor profile, which is either selected via ModBus interface or using a small add-on print that translates ModBus to 0-10V signal. If add-on print is selected, the motor selection is easily set via dip switches.
If you do not find exactly your selected compressor in the engine profile list, we are happy to help tune the SpeedControl 1145 so that it controls your compressor as best as possible.
As a rule, new profiles are tuned in our workshop, but in some cases it may be possible to perform the tuning remotely online.
By default, you can choose between cooling plate with horizontal or vertical ribs or ColdPlate. If you want a different cooling plate, a solution can be found in collaboration with our development department
Do you want to know how SpeedControl 1145 fits your product configuration?
Since 1969, we have been supplying electronics for control, regulation and control to quality-conscious companies
Get important information about products which get you ahead of your competitors, the market, technical stuff and much more. All for free and just 4-6 times a year.